Efficiency
Inverter Solis 36K-5G with a maximum input power of up to 47 kW. The maximum efficiency of the system is 98.8%. Thanks to the built-in flexible scheme, the impact on the environment is significantly reduced. It works almost silently and ensures comfortable work and the high efficiency of the inverter.
Solis inverters stand out for their exceptional durability and compact design.

Stable warranty
SOLARA cooperates with experienced international companies, which are considered the best in the field. The company guarantees the high quality and efficiency of the inverters presented. All inverters are certified to international standards and pass multi-level testing.
SOLARA ensures uninterrupted product performance and efficiency by providing a 10-year warranty on all inverter.

 

Output AC

Rated output power 36 kW
Max. apparent output power 39.6 kVA
Max. output power 39.6 kW
Rated grid voltage 3/N/PE, 220 V / 380 V, 230 V / 400V
Rated grid frequency 50 Hz / 60 Hz
Mains voltage range 320-460 V
Network frequency range 45-55 Hz / 55-65 Hz
Rated grid output current 54.7 A / 52.0 A
Max. output current 60.2 A
Power Factor >0.99 (0.8 leading - 0.8 lagging)
THDi <3%

Efficiency

Max. efficiency 98.8%
EU efficiency 98.3%

Protection

DC reverse-polarity protection Yes
Short circuit protection Yes
Output over current protection Yes
Surge protection DC Type II / AC Type II
Grid monitoring Yes
Anti-islanding protection Yes
Temperature protection Yes
Strings monitoring Yes 
I/V Curve scanning Yes 
Integrated PID recovery Optional
Integrated AFCI (DC arc-fault circuit protection) Yes (Activation required)
Integrated DC switch Optional

General Data

Dimensions (W*H*D) 647*629*252 mm
Weight 45 kg
Topology Transformerless
Self-consumption (night) <1 W
Operating ambient temperature range -25 ~ +60°C
Relative humidity 0-100%
Ingress protection IP65
Cooling concept Natural convection
Max. operation altitude 4000 m
Safety/EMC standard IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
Grid connection standard G98 or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530

Features

DC connection MC4 connector
AC connection OT terminal
Display LCD